No.SourceProperty dateStoreys/LocationProperty TypeSummary  InformationHazardLink
1CLG1950sGround FloorPre-fabricated bungalowThere is evidence that the asbestos sheet insulation to the pre-fabricated wall panels is breaking down. No hazard warnings are present. The extent of the breakdown of the asbestos means that the likelihood of a hazardous event occurring within a 12 month period is relatively high.CExample 1
2CLG1950sTop floor 2-bedroomed flat4 storey walk up block of mansion flatsThe flat was upgraded for fire proofing in the early 1960s. The wooden front door has been lined internally with 8mm ‘chrysotile’ (white) asbestos cement sheet; some of the sheeting has broken away around the point where it has been shaped to accommodate the door locks. This has resulted in some fraying and the exposure of the asbestos fibres. Above and below the locks, a cover strip running around the sides of the door, designed to protect the edge of the asbestos sheeting, is also missingBExample 2