HHSRS: November
2007
BCC - 17.1 - November 2007
Hygiene, Sanitation
Drainage
Personal
&
Vulnerable age
Related hazards
Persons aged under 5 years
Crowding & Space & Food Safety
Multiple locations
Yes
No
Secondary hazards
Yes
No
Floor Plans of Property
Dwelling: Second floor back left hand bed/study in a
pre 1920, 3 storey, HMO
DESCRIPTION OF HAZARDS
Background: This is a 3 storey, pre-1920, HMO. The accommodation comprises of nine bed-study rooms
of good size with shared use of a large lounge, a large kitchen-diner, a further kitchen and two reasonably
sized bath/shower rooms. The arrangement of rooms is as shown above. The shower room on the ground
floor comprises shower, wash basin and WC. The bathroom on the first floor provides a bath, wash basin
and WC. Both rooms have solid timber doors with privacy bolts. These facilities are in good condition, fully
functioning and adequately ventilated and illuminated. There are no wash-hand basins in any of the
individual bed/study rooms.
LIST OF RELEVANT MATTERS
LIKELIHOOD & OUTCOMES
Personal Hygiene
a
Baths or showers
1
b
Wash-hand basins
1
c
Hot and cold water supply
-
d
Kitchen sink
-
e
Clothes drying facilities
-
f
Disrepair to facilities
-
g
Inadequate lighting
-
h
Shared facilities
1
n
Effective flush
-
o
Macerator defects
-
p
Earth closet defects
-
q
Seat/lid to sanitary closet
-
r
Ventilation to compartment
-
s
Unhygienic compartment
-
t
Inadequate lighting
-
u
Door to compartment
-
v
Adjacent wash-hand basin
-
Sanitation Facilities
-
Sewage system
-
Sanitary provision
1
Sanitary closet siting
-
Disrepair to sanitary closet
-
Water to WC
-
Drainage
w
Soil and waste pipe provision
x
Pipe defects
-
-
-
-
-
-
-
-
-
-
Traps and water seals
Ventilation of pipes
Disrepair to system
Private sewage system
Soakaway
Surface water drainage
Recycling system
y
z
I
j
k
l
m
Key
aa
3 Seriously defective
bb
2 Defective
cc
1 Not satisfactory
dd
-
Satisfactory/NA
ee
J
I
RATING
2.2
21.5
Av: 76.0
76.3
Score: 17
A B C D E
F G H
I
Average likelihood and health outcomes for all persons aged under 5 years in a pre 1920
flat,1997-99.
NEW RATING
Av: Nos
Score: 2
J
BCC - 17.1 - November 2007
HEALTH AND SAFETY RATING SYSTEM SCORES
LIKELIHOOD
1 in
560
Low
High
Av: Pre 1920 Flat: 5,790
< 4200 2400 1300 750 420 240 130
75
42
24
13
7.5
4
2.5
1.5 >
Justification
The sharing of a small number of sanitary facilities amongst the nine occupiers in this property increases the
chances of spread of infection by means of faecal-oral transmission substantially more than in a property
where facilities are not shared. The lack of individual wash basins to the dwellings is likely to be a
disincentive to wash hands at any time other than after when using the bathroom/WC. The likelihood takes
no account of the quality of management and whether the facilities are regularly cleaned - they are capable
of being maintained clean - and only the level of provision.
OUTCOMES
Class I
Class II
%
Av pre 1920 flat: 0.0
0
< 0.05 0.15 0.3
0.7
1.5
3
7
15
26
38 >
Av: 2.0
RATING SCORES AFTER IMPROVEMENT
IMPROVE
Likelihood to
1 in 5600
Outcomes to
0
2.2 21.5 76.3
%
Justification
Provision of a wash hand basin in the letting would reduce the likelihood to the average.
Av: 2
< 0.05 0.15 0.3
0.7
1.5
3
7
15
26
38 >
Av: 22.0
Class III
< 0.05 0.15 0.3
0.7
1.5
3
7
15
26
38 >
Class IV
< 0.05 0.15 0.3
0.7
1.5
3
7
15
26
38 >
Justification
There is nothing to suggest that the outcomes would vary from the average
Av: Pre 1920 Flat: 2
A B C D E
F G H